User note for fluorescence highest sensitivity 1.4mp monochrome CCD camera for microscope, OCCD01400KPA-C

Key Features:
- Super quantum efficiency up to 65%
- Extremely low noise, down to 4e -rms
- 12bit dynamic range at the hardware level and 8 bit to the PC
- High resolution ( 1376 x 1040pixel)
- Shutter / exposure times from 500ns -1000s
| - Shutter / exposure times from 500ns -1000s
- Binning ( H & V)
- Region of interest ( ROI)
- 10 frames per second at full CCD resolution
- Free software included
|
Areas of Application:
- Laser induced fluorescence
- Luorescence microscopy
- Electron microscopy
- Red and NIR fluorescence applications
- Bioluminescence / chemo luminescence
- Spectroscopy
| - Gel imaging
- Ion imaging
- Low light level imaging
- Semiconductor quality control
- Imaging of bio markers (e.g. green fluorescent protein, GFP)
|
Technical Specifications:
| Sensor Format | 2/3" SONY CCD 1.4M hardware pixels |
| Pixel Size | 6.45µmx6.45µm |
| Resolution | 1376x1024 |
| Binning | 2x2 , 4x4 |
| Peak Quantum Efficiency | 62% |
| Dynamic Range | 70.1dB |
| A/D | 12 bit |
| Readout Noise | 4..5 e-rms @ gain high /5..6 e-rms @ gain low |
| Pixel Scan Rate | 16MHz |
| Spectral Range | 350-1000(w/o IR cut) , 350-780 (with IR cut) |
| Exposure Time | 133ns-582s |
| Smear | < 0.002% |
| Region of Interest | down to 32x32pixels |
| Power Supply | USB port |
| Operating Temperature | -20°C ~ 40°C |
| Operating Humidity | 10%~90% |
| Optical Input Window | fused silica |
| Data Interface | USB2.0 |
| Data transfer | Direct show and Twain interface |
| OS | Windows 2000 (Professional-SP4)-Windows XP (Professional-SP2)-Windows VISTA-Windows 2008 |
| PC requirement | CPU: Inter Pentium4 2.8GHz or higher |
| 1GB RAM or more |
| 1 Hi-speed USB 2.0Port |
| 17" or 19" Monitor |
Special Function:
- Live capture quick measure
- Video scale (e.g.100 x 20µm)
- Video Marker (e.g. size, colour, position can be changed)
- Video Date Marker
| - Video Clarity Factor
- Manual Fusion (make image large depth of field)
- Auto Fusion (Need DAF Z-axis controller)
- Auto Focus (Need DAF Z-axis controller)
|
Dimensions and Weight:
- Body length: 60mm (H)
- Body Diameter: 50mm (D)
- Cable length: 1.5m
| - Body with USB cable: 350g
- Total unit with cable weight: 600g
- Package Size: 16.5mm (L) x 14.5mm (W) x 8.5mm (H)
|
Package Includes:
- Digital Microscope C-mount Camera
- CD: Driver and Software (ScopePhoto, MiniSee)
- High-Speed USB2.0 cable (1.5m)
| - User manual
- Optional Accessories:TS-M1 or TS-M2 Calibration Slide(Stage Micrometer)
|
System Requirements:
- Intel Pentium 2.0GHz processor minimum (Recommend Dual core 2.8GHz or faster)
- Windows 2000/XP(SP2-SP3)/ Vista
- DirectX 9.0 or later
- 1GB RAM or more
| - CD-ROM drive
- 32-bit colour graphics card
- 21" display monitor or larger
- Hi-speed USB 2.0 Port
|
Download:
Basic manual (PDF format 660KB)